The ATEX Directive / IECEx Scheme and related standards like EN (IEC) 60079 and ISO 80079 define the mandatory lifetime tracking, for the total lifetime of one installation being installed in a possible hazardous area is Ex proof. Ex proof means each installation has to be identified.
ExRFID SA1 tag makes it happen in a cost effective way for longterm operation.
Passive RFID tag
Simple apparatus according to IEC 60079-14
Applicable hazardous area classification
Zone 1 IIC T6 / Zone 21 IIIC 85°C an ambient temperature Tamb 40°C
Zone 1 IIC T5 / Zone 21 IIIC 100°C at an ambient temperature Tamb 60°C
The ExRFID SA1 has to be installed on each device operated in possible hazardous areas, you need to read it out and then in a database (sheets of maintainance, repair and inspections) it has to managed. Possible hardware: tablet, smart phone, RFID reader, or any xls database or dedicated software (E.g: EPDS).
ID for mandatory lifetime tracking according to IEC 60079-14
Real time identification
Follow up inspection, operation, maintenance, repair
Connected via Ex field device, and dedicated software (customer based, E.g EPDS)
ExRFID SA1 is manufactured by Veproil Ltd.